Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38571291

RESUMEN

AIMS: Same-day discharge (SDD) after atrial fibrillation (AF) ablation is an effective means to spare healthcare resources. However, safety remains a concern, and besides structural adaptations, SDD requires more efficient logistics and coordination. Therefore, in this study, we implement a streamlined, nurse-coordinated SDD programme following a standardized protocol. METHODS AND RESULTS: As a dedicated SDD coordinator, a nurse specialized in ambulatory cardiac interventions was in charge of the full SDD protocol, including eligibility, patient flow, in-hospital logistics, patient education, and discharge as well as early post-discharge follow-up by smartphone-based virtual visits. Patients planned for AF ablation were considered eligible if they had a left ventricular ejection fraction (LVEF) ≥35%, with basic support at home and accessibility of the hospital within 60 min also forming a part of the eligibility criteria. A total of 420 consecutive patients were screened by the SDD coordinator, of whom 331 were eligible for SDD. The reasons for exclusion were living remotely (29, 6.9%), lack of support at home (19, 4.5%), or LVEF <35% (17, 4.0%). Of the eligible patients, 300 (91%) were successfully discharged the same day. There were no major post-SDD complications. Rates of unplanned medical attention (19, 6.3%) and 30-day readmission (5, 1.6%) were extremely low and driven by femoral access-site complications. These were significantly reduced upon the introduction of compulsory ultrasound-guided punctures after the initial 150 SDD patients (P = 0.0145). Standardized SDD coordination resulted in efficient workflows and reduced the total workload of the medical staff. CONCLUSION: Same-day discharge after AF ablation following a nurse-coordinated standardized protocol is safe and efficient. The concept of ambulatory cardiac intervention nurses functioning as dedicated coordinators may be key in the future transition of hospitals to SDD. Ultrasound-guided femoral puncture virtually eliminated relevant femoral access-site complications in our cohort and should therefore be a prerequisite for SDD.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Alta del Paciente , Volumen Sistólico , Cuidados Posteriores , Función Ventricular Izquierda , Estudios Retrospectivos , Resultado del Tratamiento
2.
Heart Rhythm ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38636930

RESUMEN

BACKGROUND: Atrial arrhythmogenic substrate is a key determinant of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI), and reduced conduction-velocities have been linked to adverse outcome. However, a non-invasive method to assess such electrophysiological substrate is not available to date. OBJECTIVE: This study aimed to non-invasively assess regional conduction-velocities and their association with arrhythmia-free survival following PVI. METHODS: 52 consecutive patients scheduled for AF ablation (PVI-only) and 19 healthy controls were prospectively included and received electrocardiographic imaging (ECGi) to non-invasively determine regional atrial conduction-velocities in sinus rhythm. A novel ECGi technology obviating the need of additional CT- or CMR-imaging was applied and validated using invasive mapping. RESULTS: Mean ECGi-determined atrial conduction-velocities were significantly lower in AF-patients than in healthy controls (1.45±0.15 versus 1.64±0.15m/s; p<0.0001). Differences were particularly pronounced in a regional analysis considering only the segment with the lowest average conduction-velocity in each patient (0.8±0.22 versus 1.08±0.26m/s; p<0.0001). This average conduction velocity of the "slowest" segment was independently associated with arrhythmia recurrence and better discriminated between PVI-responders and non-responders than previously proposed predictors including left atrial size or late-gadolinium-enhancement (MRI). Patients without slow-conduction areas (mean conduction-velocity <0.78m/s) showed significantly higher 12-months arrhythmia-free survival than those with one or more slow-conduction areas (88.9% versus 48.0%, p=0.002). CONCLUSIONS: This is the first study to investigate regional atrial conduction velocities non-invasively. The absence of ECGi-determined slow-conduction areas well discriminates PVI-responders from non-responders. Such non-invasive assessment of electrical arrhythmogenic substrate may guide treatment strategies and be a step towards personalised AF therapy.

3.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38262674

RESUMEN

AIMS: Non-invasive myocardial scar characterization with cardiac magnetic resonance (CMR) has been shown to accurately identify conduction channels and can be an important aid for ventricular tachycardia (VT) ablation. A new mapping method based on targeting deceleration zones (DZs) has become one of the most commonly used strategies for VT ablation procedures. The aim of the study was to analyse the capability of CMR to identify DZs and to find predictors of arrhythmogenicity in CMR channels. METHODS AND RESULTS: Forty-four consecutive patients with structural heart disease and VT undergoing ablation after CMR at a single centre (October 2018 to July 2021) were included (mean age, 64.8 ± 11.6 years; 95.5% male; 70.5% with ischaemic heart disease; a mean ejection fraction of 32.3 ± 7.8%). The characteristics of CMR channels were analysed, and correlations with DZs detected during isochronal late activation mapping in both baseline maps and remaps were determined. Overall, 109 automatically detected CMR channels were analysed (2.48 ± 1.15 per patient; length, 57.91 ± 63.07 mm; conducting channel mass, 2.06 ± 2.67 g; protectedness, 21.44 ± 25.39 mm). Overall, 76.1% of CMR channels were associated with a DZ. A univariate analysis showed that channels associated with DZs were longer [67.81 ± 68.45 vs. 26.31 ± 21.25 mm, odds ratio (OR) 1.03, P = 0.010], with a higher border zone (BZ) mass (2.41 ± 2.91 vs. 0.87 ± 0.86 g, OR 2.46, P = 0.011) and greater protectedness (24.97 ± 27.72 vs. 10.19 ± 9.52 mm, OR 1.08, P = 0.021). CONCLUSION: Non-invasive detection of targets for VT ablation is possible with CMR. Deceleration zones found during electroanatomical mapping accurately correlate with CMR channels, especially those with increased length, BZ mass, and protectedness.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Frecuencia Cardíaca/fisiología , Arritmias Cardíacas , Cicatriz/patología , Ablación por Catéter/métodos
5.
Eur Heart J Cardiovasc Imaging ; 25(2): 188-198, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-37819047

RESUMEN

AIMS: Conducting channels (CCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular tachycardia (VT). The aim of this work was to study the ability of post-ablation LGE-CMR to evaluate ablation lesions. METHODS AND RESULTS: This is a prospective study of consecutive patients referred for a scar-related VT ablation. LGE-CMR was performed 6-12 months prior to ablation and 3-6 months after ablation. Scar characteristics of pre- and post-ablation LGE-CMR were compared. During the study period (March 2019-April 2021), 61 consecutive patients underwent scar-related VT ablation after LGE-CMR. Overall, 12 patients were excluded (4 had poor-quality LGE-CMR, 2 died before post-ablation LGE-CMR, and 6 underwent post-ablation LGE-CMR 12 months after ablation). Finally, 49 patients (age: 65.5 ± 9.8 years, 97.9% male, left ventricular ejection fraction: 34.8 ± 10.4%, 87.7% ischaemic cardiomyopathy) were included. Post-ablation LGE-CMR showed a decrease in the number (3.34 ± 1.03 vs. 1.6 ± 0.2; P < 0.0001) and mass (8.45 ± 1.3 vs. 3.5 ± 0.6 g; P < 0.001) of CCs. Arrhythmogenic CCs disappeared in 74.4% of patients. Dark core was detected in 75.5% of patients, and its presence was not related to CC reduction (52.2 ± 7.4% vs. 40.8 ± 10.6%, P = 0.57). VT recurrence after one year follow-up was 16.3%. The presence of two or more channels in the post-ablation LGE-CMR was a predictor of VT recurrence (31.82% vs. 0%, P = 0.0038) with a sensibility of 100% and specificity of 61% (area under the curve 0.82). In the same line, a reduction of CCs < 55% had sensibility of 100% and specificity of 61% (area under the curve 0.83) to predict VT recurrence. CONCLUSION: Post-ablation LGE-CMR is feasible, and a reduction in the number of CCs is related with lower risk of VT recurrence. The dark core was not present in all patients. A decrease in VT substrate was also observed in patients without a dark core area in the post-ablation LGE-CMR.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Miocardio/patología , Medios de Contraste , Imagen por Resonancia Cinemagnética/métodos , Cicatriz/patología , Estudios Prospectivos , Gadolinio , Imagen por Resonancia Magnética/métodos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/patología , Espectroscopía de Resonancia Magnética
6.
J Cardiovasc Electrophysiol ; 34(11): 2286-2295, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37681321

RESUMEN

INTRODUCTION: Prediction of recurrent ventricular arrhythmia (VA) in survivors of an out-of-hospital cardiac arrest (OHCA) is important, but currently difficult. Risk of recurrence may be related to presence of myocardial scarring assessed with late gadolinium enhancement cardiac magnetic resonance (LGE-CMR). Our study aims to characterize myocardial scarring as defined by LGE-CMR in survivors of a VA-OHCA and investigate its potential role in the risk of new VA events. METHODS: Between 2015 and 2022, a total of 230 VA-OHCA patients without ST-segment elevation myocardial infarction had CMR before implantable cardioverter-defibrillator implantation for secondary prevention at Copenhagen University Hospital, Rigshospitalet, and Hospital Clínic, University of Barcelona, of which n = 170 patients had a conventional (no LGE protocol) CMR and n = 60 patients had LGE-CMR (including LGE protocol). Scar tissue including core, border zone (BZ) and BZ channels were automatically detected by specialized investigational software in patients with LGE-CMR. The primary endpoint was recurrent VA. RESULTS: After exclusion, n = 52 VA-OHCA patients with LGE-CMR and a mean left ventricular ejection fraction of 49 ± 16% were included, of which 18 (32%) patients reached the primary endpoint of VA. Patients with recurrent VA in exhibited greater scar mass, core mass, BZ mass, and presence of BZ channels compared with patients without recurrent VA. The presence of BZ channels identified patients with recurrent VA with 67% sensitivity and 85% specificity (area under the ROC curve (AUC) 0.76; 95% CI: 0.63-0.89; p < .001) and was the strongest predictor of the primary endpoint. CONCLUSIONS: The presence of BZ channels was the strongest predictor of recurrent VA in patients with an out of-hospital cardiac arrest and LGE-CMR.


Asunto(s)
Cicatriz , Paro Cardíaco Extrahospitalario , Humanos , Cicatriz/diagnóstico por imagen , Cicatriz/etiología , Medios de Contraste , Volumen Sistólico , Paro Cardíaco Extrahospitalario/diagnóstico , Paro Cardíaco Extrahospitalario/terapia , Función Ventricular Izquierda , Gadolinio , Arritmias Cardíacas , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Valor Predictivo de las Pruebas
8.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37751383

RESUMEN

AIMS: Recurrence of arrhythmia after catheter ablation of atrial fibrillation (AF) in the form of atypical atrial flutter (AFL) is common among a significant number of patients and often requires redo ablation with limited success rates. Identifying patients at high risk of AFL after AF ablation could aid in patient selection and personalized ablation approach. The study aims to assess the relationship between pre-existing atrial cardiomyopathy and the occurrence of AFL following AF ablation. METHODS AND RESULTS: We analysed a cohort of 1007 consecutive AF patients who underwent catheter ablation and were included in a prospective registry. Patients who did not have baseline cardiac magnetic resonance imaging and late gadolinium enhancement (LGE-CMR) or did not experience any recurrences were excluded. A total of 166 patients were included gathering 56 patients who underwent re-ablation due to AFL recurrences and 110 patients who underwent re-ablation due to AF recurrences (P = 0.11). A multiparametric assessment of atrial cardiomyopathy was based on basal LGE-CMR, including left atrial (LA) volume, LA sphericity, and global and segmental LA fibrosis using semiautomated post-processing software. Out of the initial cohort of 1007 patients, AFL and AF occurred in 56 and 110 patients, respectively. An age higher than 65 [odds ratio (OR) = 5.6, 95% confidence interval (CI): 2.2-14.4], the number of previous ablations (OR = 3.0, 95% CI: 1.2-7.8), and the management of ablation lines in the index procedure (OR = 2.5, 95% CI: 1.0-6.3) were independently associated with AFL occurrence. Furthermore, several characteristics assessed by LGE-CMR were identified as independent predictors of AFL recurrence after the index ablation for AF, such as enhanced LA sphericity (OR = 1.3, 95% CI: 1.1-1.6), LA global fibrosis (OR = 1.03, 95% CI: 1.01-1.07), and increased fibrosis in the lateral wall (OR = 1.03, 95% CI: 1.01-1.04). CONCLUSION: Advanced atrial cardiomyopathy assessed by LGE-CMR, such as increased LA sphericity, global LA fibrosis, and fibrosis in the lateral wall, is independently associated with arrhythmia recurrence in the form of AFL following AF ablation.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Cardiomiopatías , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Medios de Contraste , Gadolinio , Imagen por Resonancia Magnética , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico por imagen , Ablación por Catéter/efectos adversos , Espectroscopía de Resonancia Magnética
9.
Heart Lung Circ ; 32(10): 1198-1206, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37634968

RESUMEN

BACKGROUND: Atrial myopathy may underlie the progression of atrial fibrillation (AF) from a treatable disease to an irreversible condition with poor ablation outcomes. Electrophysiological methods to unmask areas prone to re-entry initiation could be key to defining latent atrial myopathy. METHODS: Consecutive patients referred for AF ablation were prospectively included at four institutions. Decrement evoked potential mapping (DEEP) was performed in eight left atrial sites and five right atrial sites, from two different pacing locations (endocardially from the left atrial appendage, epicardially from the proximal coronary sinus). The electrograms (EGMs) during S1 600 ms drive and after an extra stimulus (S2 at +30 ms above atrial refractoriness) were studied at each location and assessed for decremental properties. Follow-up was 12 months. RESULTS: Seventy-four patients were included and 85% had persistent AF. A total of 17,614 EGMs were individually analysed and measured. Nine percent of the EGMs showed DEEP properties (local delay of >10 ms after S2) with a mean decrement of 33±26 ms. DEEPs were more frequent in the left atrium than the right atrium (9.4% vs 8.0%; p<0.001) and more prevalent in persistent AF patients than paroxysmal AF patients (9.8% vs 4.6% p=0.001). Atrial DEEPs were more frequently unmasked in normal bipolar voltage areas and by epicardial pacing than endocardial pacing (9.6% vs 8.4%, respectively; p=0.004). Within the left atrium, the roof had the highest prevalence of DEEP EGMs. CONCLUSIONS: DEEP mapping of both atria is useful for highlighting areas with a tendency for unidirectional block and re-entry initiation. Those areas are more easily unmasked by epicardial pacing from the coronary sinus and more prevalent in persistent AF patients than in paroxysmal AF patients.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Enfermedades Musculares , Humanos , Atrios Cardíacos , Apéndice Atrial/cirugía , Enfermedades Musculares/cirugía , Potenciales Evocados
10.
JACC Clin Electrophysiol ; 9(6): 779-789, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37380313

RESUMEN

BACKGROUND: A new functional mapping strategy based on targeting deceleration zones (DZs) has become one of the most commonly used strategies within the armamentarium of substrate-based ablation methods for ventricular tachycardia (VT) in patients with structural heart disease. The classic conduction channels detected by voltage mapping can be accurately determined by cardiac magnetic resonance (CMR). OBJECTIVES: The purpose of this study was to analyze the evolution of DZs during ablation and their correlation with CMR. METHODS: Forty-two consecutive patients with scar-related VT undergoing ablation after CMR in Hospital Clinic (October 2018-December 2020) were included (median age 65.3 ± 11.8 years; 94.7% male; 73.7% ischemic heart disease). Baseline DZs and their evolution in isochronal late activation remaps were analyzed. A comparison between DZs and CMR conducting channels (CMR-CCs) was realized. Patients were prospectively followed for VT recurrence for 1 year. RESULTS: Overall, 95 DZs were analyzed, 93.68% of which were correlated with CMR-CCs: 44.8% located in the middle segment and 55.2% located in the entrance/exit of the channel. Remapping was performed in 91.7% of patients (1 remap: 33.3%, 2 remaps: 55.6%, and 3 remaps: 2.8%). Regarding the evolution of DZs, 72.2% disappeared after the first ablation set, with 14.13% not ablated at the end of the procedure. A total of 32.5% of DZs in remaps correlated with a CMR-CCs already detected, and 17.5% were associated with an unmasked CMR-CCs. One-year VT recurrence was 22.9%. CONCLUSIONS: DZs are highly correlated with CMR-CCs. In addition, remapping can lead to the identification of hidden substrate initially not identified by electroanatomic mapping but detected by CMR.


Asunto(s)
Desaceleración , Taquicardia Ventricular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Imagen por Resonancia Magnética , Corazón , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Espectroscopía de Resonancia Magnética
11.
Cardiol Clin ; 41(3): 333-347, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37321685

RESUMEN

The peculiar electrophysiological properties of the sinoatrial node and the cardiac conduction system are key components of the normal physiology of cardiac impulse generation and propagation. Multiple genes and transcription factors and metabolic proteins are involved in their development and regulation. In this review, we have summarized the genetic underlying causes, key clinical findings, and the latest available clinical evidence. We will discuss clinical diagnosis and management of the genetic conditions associated with conduction disorders that are more prevalent in clinical practice, for this reason, very rare genetic diseases presenting sinus node or cardiac conduction system abnormalities are not discussed.


Asunto(s)
Sistema de Conducción Cardíaco , Nodo Sinoatrial , Humanos , Frecuencia Cardíaca , Electrocardiografía
12.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37294671

RESUMEN

AIMS: To define a stepwise application of left bundle branch pacing (LBBP) criteria that will simplify implantation and guarantee electrical resynchronization. Left bundle branch pacing has emerged as an alternative to biventricular pacing. However, a systematic stepwise criterion to ensure electrical resynchronization is lacking. METHODS AND RESULTS: A cohort of 24 patients from the LEVEL-AT trial (NCT04054895) who received LBBP and had electrocardiographic imaging (ECGI) at 45 days post-implant were included. The usefulness of ECG- and electrogram-based criteria to predict accurate electrical resynchronization with LBBP were analyzed. A two-step approach was developed. The gold standard used to confirm resynchronization was the change in ventricular activation pattern and shortening in left ventricular activation time, assessed by ECGI. Twenty-two (91.6%) patients showed electrical resynchronization on ECGI. All patients fulfilled pre-screwing requisites: lead in septal position in left-oblique projection and W paced morphology in V1. In the first step, presence of either right bundle branch conduction delay pattern (qR or rSR in V1) or left bundle branch capture Plus (QRS ≤120 ms) resulted in 95% sensitivity and 100% specificity to predict LBBP resynchronization, with an accuracy of 95.8%. In the second step, the presence of selective capture (100% specificity, only 41% sensitivity) or a spike-R <80 ms in non-selective capture (100% specificity, sensitivity 46%) ensured 100% accuracy to predict resynchronization with LBBP. CONCLUSION: Stepwise application of ECG and electrogram criteria may provide an accurate assessment of electrical resynchronization with LBBP (Graphical abstract).


Asunto(s)
Fascículo Atrioventricular , Terapia de Resincronización Cardíaca , Humanos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Sistema de Conducción Cardíaco , Resultado del Tratamiento
14.
Eur Heart J Open ; 3(1): oeac085, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36654964

RESUMEN

Aims: With recurrence rates up to 50% after pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF), predictive tools to improve patient selection are needed. Patient selection based on left atrial late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) has been proposed previously (UTAH-classification). However, this approach has not been widely established, in part owed to the lack of standardization of the LGE quantification method. We have recently established a standardized LGE-CMR method enabling reproducible LGE-quantification. Here, the ability of this method to predict outcome after PVI was evaluated. Methods and results: This dual-centre study (n = 219) consists of a prospective derivation cohort (n = 37, all persistent AF) and an external validation cohort (n = 182; 66 persistent, 116 paroxysmal AF). All patients received an LGE-CMR prior to first-time PVI-only ablation. LGE was quantified based on the signal-intensity-ratio relative to the blood pool, applying a uniform LGE-defining threshold of >1.2.  In patients with persistent AF in the derivation cohort, left atrial LGE-extent above a cut-off value of 12% was found to best predict relevant low-voltage substrate (≥2 cm two with <0.5 mV during sinus rhythm) and arrhythmia-free survival 12 months post-PVI. When applied to the external validation cohort, this cut-off value was also predictive of arrhythmia-free survival for both, the total cohort and the subgroup with persistent AF (LGE < 12%: 80% and 76%; LGE > 12%: 55% and 44%; P = 0.007 and P = 0.029, respectively). Conclusion: This dual-centre study established and validated a standardized, reproducible LGE-CMR method discriminating PVI responders from non-responders, which may improve choice of therapeutic approach or ablation strategy for patients with persistent AF.

15.
Europace ; 25(2): 360-365, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36125227

RESUMEN

AIMS: Electrical reconnection of pulmonary veins (PVs) is considered an important determinant of recurrent atrial fibrillation (AF) after pulmonary vein isolation (PVI). To date, AF recurrences almost automatically trigger invasive repeat procedures, required to assess PVI durability. With recent technical advances, it is becoming increasingly common to find all PVs isolated in those repeat procedures. Thus, as ablation of extra-PV targets has failed to show benefit in randomized trials, more and more often these highly invasive procedures are performed only to rule out PV reconnection. Here we aim to define the ability of late gadolinium enhancement (LGE)-magnetic resonance imaging (MRI) to rule out PV reconnection non-invasively. METHODS AND RESULTS: This study is based on a prospective registry in which all patients receive an LGE-MRI after AF ablation. Included were all patients that-after an initial PVI and post-ablation LGE-MRI-underwent an invasive repeat procedure, which served as a reference to determine the predictive value of non-invasive lesion assessment by LGE-MRI.: 152 patients and 304 PV pairs were analysed. LGE-MRI predicted electrical PV reconnection with high sensitivity (98.9%) but rather low specificity (55.6%). Of note, LGE lesions without discontinuation ruled out reconnection of the respective PV pair with a negative predictive value of 96.9%, and patients with complete LGE lesion sets encircling all PVs were highly unlikely to show any PV reconnection (negative predictive value: 94.4%). CONCLUSION: LGE-MRI has the potential to guide selection of appropriate candidates and planning of the ablation strategy for repeat procedures and may help to identify patients that will not benefit from a redo-procedure if no ablation of extra-PV targets is intended.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Medios de Contraste , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Gadolinio , Resultado del Tratamiento , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Imagen por Resonancia Magnética , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
16.
Nat Cardiovasc Res ; 2(12): 1291-1309, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38665938

RESUMEN

Timothy syndrome 1 (TS1) is a multi-organ form of long QT syndrome associated with life-threatening cardiac arrhythmias, the organ-level dynamics of which remain unclear. In this study, we developed and characterized a novel porcine model of TS1 carrying the causative p.Gly406Arg mutation in CACNA1C, known to impair CaV1.2 channel inactivation. Our model fully recapitulated the human disease with prolonged QT interval and arrhythmic mortality. Electroanatomical mapping revealed the presence of a functional substrate vulnerable to reentry, stemming from an unforeseen constitutional slowing of cardiac activation. This signature substrate of TS1 was reliably identified using the reentry vulnerability index, which, we further demonstrate, can be used as a benchmark for assessing treatment efficacy, as shown by testing of multiple clinical and preclinical anti-arrhythmic compounds. Notably, in vitro experiments showed that TS1 cardiomyocytes display Ca2+ overload and decreased peak INa current, providing a rationale for the arrhythmogenic slowing of impulse propagation in vivo.

17.
J Innov Card Rhythm Manag ; 13(9): 5147-5152, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36196238

RESUMEN

Decrement evoked potentials (EPs) (DeEPs) constitute an accepted method to identify physiological ventricular tachycardia (VT) ablation targets without inducing VT. The feasibility of automated software (SW) in the detection of arrhythmogenic VT substrate has been documented. However, multicenter validation of automated SW and workflow has yet to be characterized. The objective of this study was to describe the functionality of a novel DeEP SW (Biosense Webster, Diamond Bar, CA, USA) and evaluate the independent performance of the automated algorithm using multicenter data. VT ablation cases were performed in the catheterization laboratory and retrospectively analyzed using the DeEP SW. The algorithm indicated and mapped DeEPs by first identifying capture in surface electrocardiograms (ECGs). Once capture was confirmed, the EPs of S1 paces were detected. The algorithm checked for the stability of S1 EPs by comparing the last 3 of the 8 morphologies and attributing standard deviation values. The extra-stimulus EP was then detected by comparing it to the S1 EP. Once detected, the DeEP value was computed from the extra-stimulus and displayed as a sphere on a voltage map. A total of 5,885 DeEP signals were extracted from 21 substrate mapping cases conducted at 3 different centers (in Spain, Canada, and Australia). A gold standard was established from ECGs manually marked by subject experts. Once the algorithm was deployed, 91.6% of S2 algorithm markings coincided with the gold standard, 1.9% were false-positives, and 0.1% were false-negatives. Also, 6.4% were non-specific DeEP detections. In conclusion, the automated DeEP algorithm identifies and displays DeEP points, revealing VT substrates in a multicenter validation study. The automation of identification and mapping display is expected to improve efficiency.

18.
J Cardiovasc Dev Dis ; 9(9)2022 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-36135433

RESUMEN

Catheter ablation of ventricular tachycardia has demonstrated its important role in the treatment of ventricular tachycardia in patients with structural cardiomyopathy. Conventional mapping techniques used to define the critical isthmus, such as activation mapping and entrainment, are limited by the non-inducibility of the clinical tachycardia or its poor hemodynamic tolerance. To overcome these limitations, a voltage mapping strategy based on bipolar electrograms peak to peak analysis was developed, but a low specificity (30%) for VT isthmus has been described with this approach. Functional mapping strategy relies on the analysis of the characteristics of the electrograms but also their propagation patterns and their response to extra-stimulus or alternative pacing wavefronts to define the targets for ablation. With this review, we aim to summarize the different functional mapping strategies described to date to identify ventricular arrhythmic substrate in patients with structural heart disease.

19.
Arrhythm Electrophysiol Rev ; 10(3): 181-189, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34777823

RESUMEN

Extensive knowledge of the anatomy of the atrioventricular conduction axis, and its branches, is key to the success of permanent physiological pacing, either by capturing the His bundle, the left bundle branch or the adjacent septal regions. The inter-individual variability of the axis plays an important role in underscoring the technical difficulties known to exist in achieving a stable position of the stimulating leads. In this review, the key anatomical features of the location of the axis relative to the triangle of Koch, the aortic root, the inferior pyramidal space and the inferoseptal recess are summarised. In keeping with the increasing number of implants aimed at targeting the environs of the left bundle branch, an extensive review of the known variability in the pattern of ramification of the left bundle branch from the axis is included. This permits the authors to summarise in a pragmatic fashion the most relevant aspects to be taken into account when seeking to successfully deploy a permanent pacing lead.

20.
Card Electrophysiol Clin ; 13(4): 625-639, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34689891

RESUMEN

The peculiar electrophysiological properties of the sinoatrial node and the cardiac conduction system are key components of the normal physiology of cardiac impulse generation and propagation. Multiple genes and transcription factors and metabolic proteins are involved in their development and regulation. In this review, we have summarized the genetic underlying causes, key clinical findings, and the latest available clinical evidence. We will discuss clinical diagnosis and management of the genetic conditions associated with conduction disorders that are more prevalent in clinical practice, for this reason, very rare genetic diseases presenting sinus node or cardiac conduction system abnormalities are not discussed.


Asunto(s)
Sistema de Conducción Cardíaco , Nodo Sinoatrial , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...